Warnings, Uses – Caple MOT900 User Manual

Page 5

Advertising
background image

5

* Please disconnect the appliance from power

mains, before carrying out any cleaning or

maintenance operation.

If the appliance is not equipped with a non-

separable flexible cable and plug, or with

another device ensuring omnipolar discon-

nection from the mains, with an opening

distance between the contacts of at least 3

mm, then such disconnecting devices must

be provided in the fixed installation.

If the appliance is equipped with a power

cord and a plug, it shall be placed in such a

way that the plug can be reached easily.

* The use of materials which can burst into

flames (flambé) should be avoided in clo-

se proximity of the appliance. When frying,

please pay particular attention to fire risk

due to oil and grease. Being highly inflam-

mable, fried oil is especially dangerous. Do

not use uncovered electric grills.

In order to avoid possible fire risk, all in-

structions for grease-filter cleaning and

for removing eventual grease deposits

should be strictly followed.

WARNINGS

* The appliance is not intended for use by

young children or infirm persons without

supervision. Young children should be su-

pervised to ensure they do not play with

the appliance.

* The minimum distance between the

cook-top surface and the lower part of

the cooker hood shall be 400 mm. For

SLTR76 model, the minimum distance shall

be 650 mm.

* The air sucked can’t be conveyed throu-

gh or into a duct used to let out fumes

from appliances fed by energy other than

electric power (eg. centralized heating, ra-

diators, water-heaters, etc.).

* To evacuate the air outlet, please comply

with the pertaining rules given by compe-

tent authorities.

* Provide the room with an adequate aeration

when a cooker hood and appliances fed by

energy other than electric power (gas-, oil-,

or coal- stoves, etc.) are used simultaneously.

The cooker hood, when evacuating the sucked

air, could generate a negative pressure in the

room- which can’t exceed the limit of 0.04

mbar, in order to avoid the suck of exhausts

deriving from the heat-source. Therefore the

room should be provided with air-intakes to

allow a costant flow of fresh air.

If the rating lable in the cooker-hood

shows the symbol , the appliance is

built in class II° and it does not need any

earth connection.

If the rating lable in the cooker-hood does

not show the symbol , the appliance is

built in class I° and it needs the earth con-

nection.

* When performing the electrical connections

on the appliance, please make sure that the

current-tap is provided with earth connection

and that voltage values correspond to those

indicated on the label placed inside the ap-

pliance itself.

USES

The appliance has been designed to work

both in filtering and sucking mode.

* In the filtering version (fig. 1), the air and

fumes conveyed by the appliance are puri-

fied

by both a grease filter and an activated char-

coal filter, and then re-circulated into the

room through the side-grids of the chim-

ney. When the appliance works in this mode,

we recommend the use of an air deflector

(Fig.1A) to be placed on the upper part of the

pipe, allowing the air to be re-circulated into

the room .

* In the sucking version (fig. 2), fumes

are directly conveyed outside the building,

through the top or rear air out-let. The use

of a charcoal filter and air deflector is not

necessary in this case.

Advertising