* Filtering version

Fix the air deflector to the pipe bearing bra-

cket, by using the screws provided.

Fix the pipe bearing bracket to the wall and/

or ceiling (Fig.16), centred to the hood.

Connect the motor air-outlet flange to the air

deflector, by using a suitable pipe. Perform

the electric connection. Place the two orna-

mental pipes on the hood body; lift the inter-

nal pipe up until it reaches the ceiling; then

fix it to the pipe bearing bracket, by using the

two self-threaded screws provided.

WORKING

LUC600 - MOT900 Model (fig. 17)

The rotary knob (fig. 18A) allows you to select

the various functions of the appliance.

All the indicators (fig. 18B) are always lit in

the stand-by function ; functions are selected

sequentially by turning the knob ; the desired

function is set by pressing the knob.

- LIGHTS Indicator (fig. 17C)

This function allows you to switch the lights

on or off; turn the rotary control until the

function is selected, then set it by pressing

the rotary control.

- Timer Indicator (fig. 17D)

By setting this control, at any speed, the ap-

pliance will be switched off after 10 minutes.

It is necessary to select the control again in

order to exit from this function. . When the

Timer function is set , the Timer indicator

will flash and the corresponding speed indi-

cator is lit.

- Speed Indicators (fig. 17E)

They are lit accordingly to the speed set.

OFF Indicator (Fig.17F): This function allows

you to completely switch off the motor; it is

totally lit during selection and setting, while

it is in stand-by afterwards.

MOT900 Model (fig. 18)

The RAZOR model, in addition to the working

features described in the paragraph above,

has an automatic opening and closing system

of the glass panel.

The opening of the glass panel corresponds

to and varies according to the motor speed

set.

The panel is closed automatically, after the

motor is switched off.

A safety device reverses the panel direction in

case of impact with unusual surfaces during

its normal travel.

All of the appliances are equipped with an

electronic device allowing for automatic

switching off after four hour working from

the last operation performed.