TABLE FOR THE CHOICE OF THE INJECTORS

Cat:

II

2H3+

GB

13

I

NCREASE OF AIR NECESSARY FOR GAS COMBUSTION

(2 m

3

/h x kW)

BURNERS

Air necessary for combustion [m

3

/h]

Auxiliary (A)

2,00

Semi-rapid (SR)

3,80

Rapid (R2)

5,90

Double-ring

6,90

Oven

12,40

Grill

9,30

G 30

- 28-30 mbar

G 20

BURNERS

G 31

- 37 mbar

20 mbar

Auxiliary (A)

1,00

0,30

27

50

3 *

72

1 *

Semi-rapid (SR)

1,90

0,38

29

67

5,7 *

100

2 *

Rapid (R2)

2,95

0,60

39

83

fully open *

125

3 *

Double-ring

3,45

0,85

47

92

fully open *

135

5 *

Oven

6,20

1,30

58

120

8 *

180

1,5 *

Grill

4,65

-

-

107

fully open *

-

165

3 *

Nominal

Power

[kW]

Reduced

Power

[kW]

Ring opening

[mm]

Ø injector

[1/100 mm]

By-pass

[1/100 mm]

Ring opening

[mm]

Ø injector

[1/100 mm]

By-pass

[1/100 mm]

adjustable

*

= Reference value