Lubrication of the gas taps, Table for the choice of the injectors – Caple CR9204 User Manual

Page 21

Advertising
background image

21

The operations must be executed by a qualified technician.

IMPORTANT

All intervention regarding installation maintenance and conversion of the

appliance must be fulfilled with original factory parts.

The manufacturer declines any liability resulting from the non-compliance of

this obligation.

Lubrication of the gas taps

TABLE FOR THE CHOICE OF THE INJECTORS

Cat: II 2H 3+

GB

G30/G31

28-30/37 mbar

G 20

20 mbar

BuRNERS

Nominal

Power

[Hs - kW]

Reduced

Power

[Hs - kW]

Ø injector

[1/100 mm]

Ø injector

[1/100 mm]

Auxiliary (A)

1,00

0,30

50

72 (X)

Semi-rapid (SR)

1,75

0,45

65

97 (Z)

Triple ring (TR)

3,50

1,50

95

135 (T)

Dual (DB)

inner crown

1,00 (#)

0,32 (#)

50

(no. 1 central)

69 (F1)

(no. 1 central)

outer crowns

4,50 (*)

1,90 (*)

66

(no. 2 outer)

102 (Z)

(no. 2 outer)

(#): Power calculated with inner crown operating.
(

*

): Power calculated with inner and outer crowns operating.

A

IR vENT NECESSARy FOR GAS COMBuSTION

= (2 m

3

/h x kW)

BuRNERS

Air necessary for combustion [m

3

/h]

Auxiliary (A)

2,00

Semi-rapid (SR)

3,50

Triple ring (TR)

7,00

Dual (DB) -

inner crown operating

2,00

Dual (DB) -

inner & outer crowns operating

9,00

Advertising