1 - Electrical Requirements

WARNING!

ELECTRICITY CAN BE EXTREMELY DANGEROUS.

THIS APPLIANCE MUST BE EARTHED.

For your safety please read the following information:

• The connection to the electrical network must be carried out by qualified personnel

and must be according to existing norms.

• The appliance must be connected to the electrical network verifying above all that

the voltage corresponds to the value indicated on the specifications plate and that
the cables section of the electrical plant can bear the load which is also indicated
on the plate.

• The appliance can be connected directly to the mains placing an omnipolar switch

with minimum opening between the contacts of 3 mm between the appliance and
the mains.

• The power supply cable must not touch the hot parts and must be positioned so

that it does not exceed 75°C at any point.

• Once the appliance has been installed, the switch must always be accessible.

• If the power supply cable is damaged it must be substituted by a suitable cable.

Before effecting any intervention on the electrical parts the appliance must be
disconnected from the network.

IMPORTANT: this double oven must be connected to a suitable double
pole control unit adjacent to the oven.

NO DIVERSITY CAN BE APPLIED TO THIS CONTROL UNIT.

The connection of the appliance to the grounding unit is mandatory.
The manufacturer declines every responsibility for any inconvenience resulting
from the inobservance of this condition.

6

FEEDER CABLE SECTION

Type HO5RR-F or H05VV-F

230 V

~

3 x 2,5 mm

2

(**)

(**) –

Connection to wall-mounting distribution panel.