RL Series and RSL Series Installation Guide v2.0

13

Wiring details

In most cases, remote control plates connect to their host devices via

per-channel, 3-pin 5 mm-pitch screw terminal connectors on the device’s

rear panel. The only exception is the CX163, which has a 4-pin connector.
The connector will be labelled

REMOTE LEVEL, REMOTE LEVEL/

SOURCE, REMOTE MUSIC CONTROL, or something similar,

depending on the device.

On all types of remote control plate, connection at the plate is via a rear 3-pin
screw-terminal connector.

RL Series plates: Connection may be via single- or twin-core screened

cable. RL Series plates can generally be connected to devices that support

remote music source selection with single-core cable, but two-core screened
cable is required when connecting to devices that do not support this.

RSL Series plates: These always require twin-core screened cable.
The use of crimp ferrule-type terminals is recommended for the cable
terminations as this will provide a much more reliable long-term connection.

Recommended maximum cable length is 100 m (328 ft.)