Cdi-s100 remote control, Pinout port parameters, Abridged command set – Cloud Electronics CDI-S100 User Manual

Page 7: Cdi-s100 remote control pinout, Port parameters

Advertising
background image

CDI-S100 Installation Guide v1.0

77

CDI-S100 Remote Control

Pinout

The rear panel serial connector is a female
9-pin Dsub. The pinout is shown in the table:

PIN

FUNCTION

1

n/u

2

Data receive

3

Data transmit

4

DTR

5

0v

6

DSR

7

RTS

8

CTS

9

n/u

For most installations, it will only be necessary
to connect pins 2, 3 and 5. If the control

system’s serial port is also a 9-pin Dsub, use a

D9-to-D9 “straight” cable (i.e. one wired with
pin 1 to pin 1, pin 2 to pin 2, etc.) If the control

system’s serial port is a screw-terminal (or

other type of) connector, the terminals will

most likely be marked “Tx”, “Rx” and “Gnd”,

or something similar. In this case, connect “Tx”

to pin 3 on the CDI-S100, “Rx” to Pin 2 and

“Gnd” to pin 5. See the following illustration
for details.

NOTE:

Not all manufacturers interpret

“Tx” and “Rx” in the same way, and it may

be necessary for a “crossed” cable to be

used instead. A crossed cable is one with

pin 2 connected to pin 3 at the other end,
and vice-versa. If your CDI-S100 appears
to ignore control system instructions and
all connections, programming, etc., appear
satisfactory, try reversing pins 2 and 3 at one
end of the serial cable.

The installer should also check whether the
control system being used requires
RS-232C flow control (or “handshaking”) to
be implemented, and if so, whether hardware
control or software control is used. Hardware

handshaking (sometimes called RTS/CTS)
requires pins 7 and 8 to be connected.

CONTROLLER

1

9

8

7

6

5

4

3

2

CDI-S100

TX

TX

RX

RX

CTS

CTS

RTS

RTS

Connect if hardware

flow control is required

“STRAIGHT” RS-232C SERIAL CABLE

Note that some installation require a “crossed” cable in this

case, pins 2 and 3 should be reversed at one end.

Port parameters

PARAMETER

VALUE/SETTING

Data type:

RS-232C serial

Data speed

300/1200/2400/4800/9600
baud, selectable by jumper

Word length

8 bits

Parity

None

Stop bits

One

Abridged command set
The commands listed in the General Format

table (page 8) are those most commonly

required. For all other commands, data

requests and responses, please refer to the

CDI-S100’s full RS-232C protocol document at

www.cloud.co.uk

.

The table provides the general format of each

type of command, The commands are given

in ASCII form; note that all characters in the
command, including the non-alphanumeric
ones, must be sent. The characters shown in
italics must be replaced by specific numeric
values when a command is sent.

Following the table, an example of each
command type is given; refer to the general
format to see how the variable characters are
replaced by specific values. The commands in
the examples are given in both ASCII and hex
form.