System regulator testing, Figure 3-20: system regulator testing, Temperature – Codan Radio MT-4E Paging User Manual

Page 36

Advertising
background image

USER GUIDE | MT-4E PAGING SYSTEMS

Chapter 3: MT-4E Paging System Components

Page 28

System Regulator Testing

The System Regulator module is designed with a convenient and easy test point built in to the front
panel. This test point allows a technician access to the DC supply and regulated voltages. Simply
connect a standard Digital Volt Meter (DVM) to the METER jacks on the front panel of the System
Regulator as shown in Figure 3-20. Turn the rotary switch to the desired position to measure the supply
voltage, regulated voltage or audio output as shown in Table 3-1. Note that the RSSI requires a carrier
and the audio output requires an audio tone injected into the receiver.

Figure 3-20: System Regulator Testing

Table 3-1: System Regulator Rotary Switch Functions

Position Function

Parameter

1

Supply Voltage

+10 Vdc to +17 Vdc (+13.8 Vdc nominal)

2

+9.5 Volts Regulated

+9.5 Vdc (± 0.1 Vdc)

3

Rx A Audio

Receiver A Audio (NOT Rx Balanced Output)

4

Rx A Carrier Strength

0 Vdc to +5.0 Vdc based on received signal strength

(0 Vdc is a low RF signal level, +5.0 Vdc is high)

5

Rx B Audio

Receiver B Audio (NOT Rx Balanced Output)

6

Rx B Carrier Strength

0 Vdc to +5.0 Vdc based on received signal strength

(0 Vdc is a low RF signal level, +5.0 Vdc is high)

TRANSMITTER

CNTL
BUS

MIC

RF OUT

A D

ANALOG
DIGITAL

NORM
OFF
KEY TX

MIC MODE

REF

IN

USB

FREQUENCY (MHz)

MADE IN CANADA

MODEL # CODE

RECEIVER

NORM

SQ. DISABLE

OFF

CNTL
BUS

A D

RF N

I

REF
IN

USB

FREQUENCY (MHz)

MADE IN CANADA

MODEL # CODE

VOL

SYSTEM REGULATOR

METER

+

-

MADE IN CANADA

ON
OFF

SPKR

INT

EXT

EXT

SPKR

OFF

POWER

ON

2

1

5

4

3

6

7

8

11

10

9

FUNCTION

12

MIN MAX

HOLD

REL

% ms

Hz

RANGE

dB

dB

ac+dc

ac+dc

ac+dc

ac+dc

F

nS

mA

mA

A

mV

V

mV

V

OFF

C

A

A

A

A

mA

COM

V

TEMPERATURE

A

MIN MAX

HOLD

REL

% ms

Hz

RANGE

dB

dB

ac+dc

ac+dc

ac+dc

ac+dc

F

nS

mA

mA

A

mV

V

mV

V

OFF

C

A

A

A

A

mA

COM

V

TEMPERATURE

A

AutoHOLD

LOGGING

SAVE

CANCEL

FAST MN MX

SETUP

YES

NO

DIGITAL MULTIMETER

CLEAR MEM

VIEW

DC

SET

DEV

4 LEVEL

SETUP

MODE

DATA
MODE

A

D

2 LEVEL

SET

MOD

NORM

REF IN

REF OUT

PAGING

MODULATOR

DATA

INT

FREQ

REF

EXT

DATA / CTRL

PORT

PULL DOWN
TO REMOVE

Advertising