Administrator guide – Code Blue 360-DEGREE PEDESTAL MOUNT PUBLIC ADDRESS SPEAKER User Manual

Page 26

Advertising
background image

Administrator Guide

Code Blue

Please contact Code Blue Technical Support if you do not see your issue below.

Remove the control cable from the amp. This will turn the amp on at all times.

7.1.1.1
Try a new test call.

Test power from the transformer to the amp.

7.1.1.2

Check the 5 amp slow blow inline fuse between the transformer and 5-finger

7.1.2.1
manifold.

Check power connector at the 5 finger manifold and the red/black power wire

7.1.2.2
from the strobe.

Short the yellow relay wires from the strobe to test strobe functionality. If the

7.1.2.3
strobe flashes, check programming in the IA4100/IP5000 speakerphone.

For CB 1 or 5 units, verify that you have 120V AC to the transformer.

7.1.3.1

For CB 2-e units, verify that you have either Hi-Voltage to the power brick or 24V

7.1.3.2
AC to the unit if low voltage only.

For WM-180° units, verify you have 24V AC to the unit

7.1.3.3

First, adjust the volume in the IA4100/IP5000 programming. On the IA4100, the

7.1.4.1
in-call command for increasing the volume is 28. To decrease the volume, the in-call
command is 29. On the IP5000, the Public Address Gain can be changed under hardware
settings.

The input gain also can be adjusted manually on the amplifier using the input gain

7.1.4.2
dial.