D.6.6 buc commands and queries (cdm-600l only) – Comtech EF Data CDM-600/600L User Manual

Page 226

Advertising
background image

CDM-600/600L Open Network Satellite Modem

Revision 3

Appendix D

MN/CDM600L.IOM

D–34

D.6.6 BUC Commands and Queries (CDM-600L ONLY)

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

BUC Address

OAD=

1 byte, value of
1 to 15

Command or Query.
Sets BUC Address, in the form xx, where:

xx= a value between 1 and 15.

Note: Valid only when the FSK and BUC power are enabled.

OAD=
OAD?
OAD*
OAD#

OAD? OAD=xx

(see Description of
Arguments)

BUC Current

N/A

4 bytes

Query only.
Unit returns the value of the BUC Current, in mA, in the form xxxx,
where:
xxxx=a value between 0 and 9999

Note: Unit returns 0000 when BUC power is turned OFF.

N/A ODC?

ODC=xxxx
(see Description of
Arguments)

BUC High
Current Limit

ODH=

4 bytes

Command or Query.
Sets BUC High Current Limit, in mA, in 100mA increments,in the
form xxxx, where:
xxxx= a value between 0 and 4000.

ODH=
ODH?
ODH*
ODH#

ODH? ODH=xxxx

(see Description of
Arguments)

BUC Low
Current Limit

ODL=

4 bytes

Command or Query.
Sets BUC Low Current Limit, in mA, in 100mA increments, in the
form xxxx, where:
xxxx= a value between 0 and 4000.

ODL=
ODL?
ODL*
ODL#

ODL? ODL=xxxx

(see Description of
Arguments)

BUC Power
enable

ODP=

1 byte, value of
0 or 1

Command or Query.
Selects BUC operation, where:

0=Disable BUC DC Power Supply
1=Enable BUC DC Power Supply

ODP=
ODP?
ODP*
ODP#

ODP? ODP=x

(see Description of
Arguments)

BUC 10 MHz
Reference

ODR=

1 byte

Command or Query.
Selects BUC 10 MHz Reference, where:
0=OFF
1=ON

ODR=
ODR?
ODR*
ODR#

ODR? ODR=x

(see Description of
Arguments)

BUC
Temperature

N/A

4 bytes

Query only.
Unit returns BUC temperature in the form sxxx, where:
s=sign
xxx=number

Note: Valid only when the FSK and BUC power are turned On.

N/A ODT?

ODT=sxxx

(see Description of
Arguments)

BUC Voltage

N/A

4 bytes

Query only.
Unit returns the value of the BUC Voltage, in volts, in the form xx.x,
where:

xx.x= a value between 0 and 64.0.

N/A

ODV?

ODV=xx.x
(see Description of
Arguments)

BUC Phase
Lock Loop

N/A

1 byte, value of
0 or 1

Query only.
Unit returns BUC phase lock loop, where:
0=Locked
1=Unlocked

Note: Valid only when the FSK and BUC power are turned On.

N/A OLL?

OLL=x

(see Description of
Arguments)

Advertising