4 config: clocks ( freq-ref, 5 config: clocks ( int-ref-adjust – Comtech EF Data CDM-625A User Manual

Page 160

Advertising
background image

CDM-625A Advanced Satellite Modem

MN-CDM625A

Front Panel Operation

Revision 3

6–34

6.2.1.5.4 CONFIG: Clocks Freq-Ref

Frequency Reference: Internal

(Internal(with O/P),1,2,5,10MHz)

()

Use the

▲▼

arrow keys to select one of the two internal reference modes – Internal and

Internal (with Output) – and then press ENTER.

Internal (with Output) mode uses the internal reference as an output on the rear panel Ext Ref

In/Out BNC connector. This mode is useful if a user wishes to use a single frequency reference

for both the modem and another piece of equipment in the system. When you select this mode,

an amber LED adjacent to the connector illuminates to alert you that the connector, normally

used as input, now has an output signal present.

6.2.1.5.5 CONFIG: Clocks Int-Ref-Adjust

Internal Hi-Stability 10MHz Reference

Fine Adjust: +048 (+/-999)

()

Use this menu for very fine adjustment of the Internal 10MHz Reference. When you select the

Internal 10 MHz Reference, the adjustment value is retained in EEPROM memory, and is

therefore not lost when the NVRAM memory is cleared.

Use the

◄ ►

arrow keys to select a digit, and then use the

▲▼

arrow keys to change that digit.

Press ENTER.

Changes made to the adjust value occur immediately upon entry, not after Pressing

the ENTER key.

Advertising