Fault connector and pinouts (j7), 2 fault connector and pinouts (j7) – Comtech EF Data C5 User Manual

Page 114

Advertising
background image

Installation

C5/K1/K3 Integrated Satellite Terminal System

3–18

Rev. 0

3.4.2

Fault Connector and Pinouts (J7)

The fault connector provides Form C contact closures for fault reporting. The three Form C
summary fault contacts are Modulator, Demodulator, and Common Equipment.

The fault interface connection is a 9-pin female D connector (J7) located on the rear panel
of the modem. Form contact; ratings 1A maximum at 24 VDC, 0.5A at 120 VAC. Screw
locks are provided for mechanical security on the mating connector. Refer to Table 3-3 for
pinout information.

Table 3-3. Fault Connector and Pinouts (J7)

Pin #

Signal Function

Name

1

Common equipment is not faulted

NO

2

COM

3

Common equipment is faulted

NC

4

TX is not faulted

NO

5

COM

6

TX is faulted

NC

7

RX is not faulted

NO

8

COM

9

RX is faulted

NC

Refer to Chapter 6 for a discussion of monitored faults. To obtain a system summary
fault, connect all the Form C contacts in parallel.