Remote Control Operation

C5/K1/K3 Integrated Satellite Terminal System

B–24

Rev. 0

Receive
Signal Level
Status

Command:
Response:

<add/RSL_'cr'
>add/RSL_xsnn.ndBm'cr''lf']

Where:

x = < or > (data modifier to indicate that the receive
signal level is less than or greater than the returned
value).

s = + or - (receive signal level sign, plus or minus).

nn.n = 0.0 to 99.9 (receive signal level magnitude).

Notes:

1. The 'x' (< or >) parameter is only returned if the level

has exceeded the computational resolution of the
system.

2. 'No Data' is returned if the level cannot be calculated.
3. 'Sampling' is returned if not enough data is currently

available to calculate the level.

Interface
Buffer Fill
Status

Command:
Response:

<add/IBFS_'cr'
>add/IBFS_nn%'cr''lf']

Where: nn = 1 to 99 (relative to buffer depth).

Current
Sweep Value

Command:
Response:

<add/CSV_'cr'
>add/CSV_xsnnnnn'cr'
CD_yyy'cr''lf']

Where:

x = < or > (data modifier to indicate that the sweep offset
value is less than or greater than the returned value).

s = + or - (sweep offset from center).

nnnnn = 0 to 35000.

yyy = OK or FLT (decoder lock status OK or FAULT).

This command returns the current sweep offset value.

Notes:

1. The 'x' (< or >) parameter is only returned if the level

has exceeded the computational resolution of the
system.

2. 'No Data' is returned if the level cannot be calculated.
3. 'Sampling' is returned if not enough data is currently

available to calculate the level.

Power
Supply
Temperature

Command:
Response:

<add/PST_'cr'
>add/PST_snnn'cr''lf']

Where:

s = + or -.
nnn = 0 to 125 (Degrees Celsius).

Note: 'No Data' is returned if the temperature cannot be read
from power supply.