Remote Control Operation

SNM-1001 Network Control Modem

A–10

Rev. 1

Interface
ADPCM
Program

Command:
Response:

Status:
Response:

<add/ADP_xxx'cr'
>add/ADP_xxx'cr''lf']

<add/ADP_'cr'
>add/ADP_xxx'cr''lf']

Where: xxx = ON or OFF.

Note: Only valid when ADPCM board is installed.

Interface
Subscriber/
Trunk
Emulation

Command:
Response:

Status:
Response:

<add/SBTR_xxx'cr'
>add/SBTR_xxx'cr''lf']

<add/SBTR_'cr'
>add/SBTR_xxx'cr''lf']

Where: xxx = SUB or TRK.

Note: Only valid when ADPCM board is installed.

E & M
Signal Type

Command:
Response:

Status:
Response:

<add/EMS_n'cr'
>add/EMS_n'cr''lf']

<add/EMS_'cr'
>add/EMS_n'cr''lf']

Where: n = 1 to 5, in steps of 1.

Note: Only valid when ADPCM board is installed.

Interface
Encoding
Law

Command:
Response:

Status:
Response:

<add/LAW_y'cr'
>add/LAW_y'cr''lf']

<add/LAW_'cr
>add/LAW_y'cr''lf']

Where: y = A (A-Law) or U (u-Law).

Off Hook
Alert Enable

Command:
Response:

Status:
Response:

<add/HOOK_xxx'cr'
>add/HOOK_xxx'cr''lf']

<add/HOOK_'cr
>add/HOOK_xxx'cr''lf']

Where: xxx = ON or OFF.

Note: Only valid when ADPCM board is installed.

Interface
Service
Channel
Level

Command:
Response:

Status:
Response:

<add/ISCL_xx_nnn'cr'
>add/ISCL_xx_nnn'cr''lf']

<add/ISCL_xx'cr'
>add/ISCL_xx_nnn'cr''lf']

Where:

xx = TX or RX (service channel designator).
nnn = -20 to +10, in steps of 1 (service channel level in
dBm).

Note: Only valid when ADPCM board is installed.

Interface
RD Signal

Command:
Response:

Status:
Response:

<add/RD_xxx'cr'
>add/RD_xxx'cr''lf']

<add/RD_'cr'
>add/RD_xxx'cr''lf']

Where: xxx = NRM or INV.

Note: Only valid when ADPCM board is installed.

Interface
SD Signal

Command:
Response:

Status:
Response:

<add/SD_xxx'cr'
>add/SD_xxx'cr''lf']

<add/SD_'cr'
>add/SD_xxx'cr''lf']

Where: xxx = NRM or INV.

Note: Only valid when ADPCM board is installed.

Interface
RR Signal

Command:
Response:

Status:
Response:

<add/RR_xxx'cr'
>add/RR_xxx'cr''lf']

<add/RR_'cr'
>add/RR_xxx'cr''lf']

Where: xxx = NRM or INV.

Note: Only valid when ADPCM board is installed.

Interface
DM Signal

Command:
Response:

Status:
Response:

<add/DM_xxx'cr'
>add/DM_xxx'cr''lf']

<add/DM_'cr'
>add/DM_xxx'cr''lf']

Where: xxx = NRM or INV.

Note: Only valid when ADPCM board is installed.

Interface
ASYNC
Communi-
cations
Program

Command:
Response:

Status:
Response:

<add/ACP_xxx'cr'
>add/ACP_xxx'cr''lf']

<add/ACP_'cr'
>add/ACP_xxx'cr''lf']

Where: xxx = ON or OFF.

Note: Only valid when ASYNC board is installed.