SNM-1001L Satellite Modem

Revision 1

Front Panel Operation

MN/SNM1001L.IOM

4–78

FUNCTION SELECT: UTILITY: OUTDOOR UNIT: ODU PWR LEVELING

(CONDITIONAL)

ODU PWR LEVELING

OFF


IMPORTANT

Conditional: This menu is available only when ODU Power Supply,
and TX-IF Output are On.


When Power Leveling is On the Modem TX-IF Output is continually adjusted to maintain the ODU
Power level set by selecting ODU PWR Leveling = On. In the On mode the modem Auto adjusts
the ODU Power Level. This requires an FSK capable ODU (BUC). The Monitor menu shows the
actual BUC Power and (T) Target Power. Press [

↑] or [↓] to select the ODU Power Leveling.

Press [ENTER] to execute the change.

4.3.6.6

FUNCTION SELECT: UTILITY:SYSTEM

UTILITY

SYSTEM


Select information to view using the [

←] [→] arrow keys, then press <ENTER>.

FUNCTION SELECT: UTILITY: SYSTEM:TIME/DATE

TIME: 12:00:00AM
DATE: 7/04/1976


Time of day and date display/set function.

The current time and date in the modem’s memory are displayed when selected. To change the
modem time and/or date, press <ENTER>. Press [

←] or [→] to position the cursor over the

parameter to be changed. Press [

↑] or [↓] to change the parameter. Once the parameters are

displayed as desired, press <ENTER> to set the time and date.