A.7.16

Receive Input Power (Desired Carrier)

The modem can meet the specified BER and automatically adjust to a receive input power.
The minimum input signal level is –135 dBm + 10 log (Symbol Rate). E.g. (-98 dBm @
4.8 Ks/s). The maximum desired input signal level is –85 dBm + 10 log (symbol rate).
Monitor accuracy is

± 7.5 dB. See Figure A-1.

Figure A-1. Carrier Level vs Symbol Rate

A.7.17

Demodulator Channel Spacing/Adjacent Carrier Performance

The modem BER will be degraded less than 0.5 dB with the following receive signal:

• Two like-modulated carriers spaced 1.3 times the symbol rate from the receive

frequency, and/or 1.2 times the acquisition range, whichever is larger.

• Each adjacent carrier up to 10 dBc higher in power than the desired carrier.
• A single adjacent carrier spaced 1.4 times the symbol rate, up to +20 dBc.

-110

-100

-90

-80

-70

-60

-50

-40

-30

-20

-10

1

10

100

1000

10000

Symbol Rate (Ksym/s)

Carrier Level (dBm)

Maximum Level

Minimum Level

Carrier Level (vs) Symbol Rate

300L_levels.xls