Comtech EF Data XSAT-7080 User Manual

Page 134

Advertising
background image

XSAT7080 X-Band Transceiver

Revision 0

50 and 100-Watt Installation

MN/XSAT7080.IOM

B–24

Step

Procedures

13

Slide bracket (3) over bracket (2).

14

Place flat washer (7) and splitlock washer (8), and nut (10) on bracket (2).

15

Tighten nut to secure the tension strap.

16

Slide two springnuts, (5, figure B-2) into channel of the Unistrut bracket
(1, figure B1).

17

Repeat procedure for second Unistrut bracket (1).

18

Install bracket (1, figure B-10) and secure to the Unistruts with four bolts
(11), and lock washers ( 10 ).

19

Install switch mount bracket (8, figure B-10), to main bracket (1). Secure with
four bolts (11), lock washer (10), and nuts (9).

20

Ensure that the bracket is centered on the Unistruts. Tighten hardware.

IMPORTANT

When installed, ensure the XSAT 100 Watt unit fan is facing outward.

21

Install brackets (1, figure B-2) and secure to Unistrut brackets with four bolts
(6), flat washers (2) and split lock washers (3).

22

Position brackets (1) against center bracket. Do not tighten hardware at this
time

23

Install four bolts (7, figure B-10) with split washers (10) , and flat washers
(2 ) into provided mounting holes in the XSAT 100 Watt casting

24

Carefully lift the unit, and slide the bolt head into the groove of bracket
(1, figure B-10 ).

25

Ensure the washers are between the unit and the bracket. Do not tighten
hardware at this time.

26

Temporary install the assembled waveguide switch (Figure B-18).

27

Ensure that the ports line-up and can be secured. If a gap is present, adjust by
sliding the unit and bracket (1, figure B-2) on the Unistrut (In or Out).