Function description, Prime power level, Physical dimensions – Comtech EF Data XSAT-7080 User Manual

Page 78: 1 function description, 2 prime power level, 3 physical dimensions

Advertising
background image

XSAT7080 X-Band Transciever

Revision 0

+10 dBm Model X-Band Transceiver

MN/XSAT7080.IOM

8–2

8.1.1

Function Description

The Transceiver is designed for use in communication systems, or in satellite uplink data
systems, for the reception of SCPC, DAMA, and TDMA communication signals. It also
can be used in communications system applications with full transponder HDTV and
analog TV. The RF operating frequency range is as follows:

Upconverter section

7900 to 8400

Downconverter section

7250 to 7750


This transceiver provides an upconverted ouput used to drive an external SSPA or
TWTA. The down conversion side of the transceiver operates the same as the higher
power versions of the same XSAT. The converter is environmentally sealed and is
designed to be hard mounted on or near the antenna structure.

CAUTION

The downconverter RF input connector is wired to supply DC voltage to an
LNA. This voltage is capable of damaging any test equipment connected to
the connector. Do not connect test equipment to the connector without a
coaxial DC block between the connector and the test equipment.

8.1.2 Prime Power Level

The power input requirements for the X-Band Downconverter is as follows:

Prime Power Level

100 to 125 Volts AC, or 205 to 240 Volts AC, 47 to 623 Hz.

Current Requirements

Typical current requirements is 1.2 amps at 100 to 125 VAC or
0.6 amps at 205 to 240 VAC.

8.1.3 Physical Dimensions

Parameter

Specification

Length

11 inches

(28 cm)

Width

8 inches

(20 cm)

Height

8 inches

(20 cm)

Weight

36 pounds

(16 kg)













Advertising