Installation, 1 general system, 2 beam and footing selection – Daktronics CH-1018V User Manual

Page 7: Installation -1, General system -1, Beam and footing selection -1

Advertising
background image

Installation

2-1

Section 2: Installation


2.1 General

System

Reference Drawings: Driver Enclosure, Power & Signal ............... Drawing A-37915

Color Code, 25-Pin J-Box ........................... Drawing A-47207
System Layout, CH-1018V.......................... Drawing A-55692
Footings & Beams, CH-1018V .................... Drawing A-55694
Display Mounting, CH-1018V...................... Drawing A-55695
Electrical Installation, CH-1018V ................ Drawing A-55699
Component Locations, CH-1018V .............. Drawing A-55700


Refer to Drawing A-55692 for a general system layout.

The general procedure for installing the CH-1018H display is as follows:

1. Select beam and footing recommendations from the table below.
2. Dig the footing holes and install beams and footings.
3. Route power and signal cables to the display and control locations.
4. Mount the displays to the beams as described in Section 2.3 and Drawings A-55694 and

A-55695.

5. Route power and signal wires into the displays as described in Section 2.4 and Drawings

A-37915, A-47207, A-55699, and A-55700.


2.2

Beam and Footing Selection

Reference Drawing: Footings & Beams, CH-1018V ...................... Drawing A-55694

The table below contains recommendations for W-shape beams and footings to support the
display as shown in Drawing A-55694. The first column is wind velocity in miles per hour.
The distance in the second column is from the ground to the bottom of the display. The
choice from these columns depends upon the display location.

The beams listed below are beams which provide maximum wind load strength for the weight
and cost of the beams.

Wind

Speed

Height

(ft)

Beam

Section

Footing

Depth x Dia.

70 mph

10

W8 x 15

4 ¾ ft x 3 ft

15

W6 x 20

5 ½ ft x 3 ft

80 mph

10

W8 x 15

5 ½ ft x 3 ft

15

W8 x 20

6 ¾ ft x 3 ft

90 mph

10

W8 x 17

6 ¼ ft x 3 ft

15

W8 x 24

7 ft x 3 ft


The calculations for footing diameters and depths are based on the assumption that footings
are in undisturbed soils, not fill soils. Lateral bearing capacity of 300 psf per foot of depth in
natural grade was used to derive these figures.