3 display mounting, 4 electrical installation, 1 control signal cable – Daktronics CH-1018V User Manual

Page 8: Display mounting -2

Advertising
background image

Installation

2-2

The footing recommendations are based on the allowable soil bearing pressure of 3000 psf
vertically and 300 psf/ft of depth horizontally. However, these recommendations are
suggestions only
and soil bearing pressure at the site must be determined by a sample test prior
to specifying actual footings. Be sure that the installation complies with local codes and is
suitable for the particular soil and wind conditions. Daktronics assumes no responsibility for
structures installed by others.
Daktronics recommends that W-sections of grade 35 steel be used
for beams, and that 28-day (strength 3000 psi) concrete be used for footings.

A note about beam nomenclature: For a typical beam, W6 x 12 for example "W" stands for
"Wide-Flange Beam". The first number (6) is the approximate front to rear dimension of the
beam in inches. The second number (12) is the weight per foot in pounds. This numbering is a
standard in the steel industry. Widths are from 6.00 to 8.00 inches in the chart above.



2.3 Display

Mounting

Reference Drawings: Footings & Beams, CH-1018V .................... Drawing A-55694

Display Mounting, CH-1018V...................... Drawing A-55695


Drawings A-55694
and A-55695 show the typical mounting for the display.

Note: The bolts that secure the display sections do not go through the beams, but run along
both sides of the beam, clamping the display to the beams.

A mounting kit consisting of mounting angles and 1/2" hardware are provided to mount the
display.

1. Position the display against the mounting beams and secure the bottom of the display to

both beams as shown in Drawing A-51757.

2. Next, secure the top of the display. Once mounting angles are attached, the display may

be slid up or down to the desired height.

3. Once positioned as desired, tighten all bolts.

2.4 Electrical

Installation

2.4.1 Control Signal Cable

Reference Drawings: Driver Enclosure, Power & Signal.... Drawing A-37915

Color Code, 25-Pin J-Box ............... Drawing A-47207
Component Locations,CH-1018V ... Drawing A-55700


For the display, two conductors of 24 AWG are needed. For distances up to 600 ft. or
22 AWG, up to 1000 ft. are required. Daktronics has 24 AWG direct burial cable,
Daktronics part no. W-1105 with 6 conductors, and 22 AWG cable that must be
pulled through the conduit before burial, Daktronics part no. W-1077 with 2
conductors.

At the control location, mount the signal J-box to a convenient location. Route the
cables and connect to the wires leading from the connector in the cover according to
the following table and Drawing A-47207.
At the display, open the bottom hinged panel covering the entrance enclosure as
shown on Drawing A-55700. Remove the cover from the entrance enclosure. Refer

Advertising