Appendix a – DFI KS200 Manual User Manual

Page 29

Advertising
background image

www.dfi.com

29

Appendix A

Appendix A Software Support

UART

TS200 provides 2 UART COM Ports. COM1 only supports RS232, and COM2 supports three

mode selections (RS232/RS485/RS422).

Path : My Device\Windows\UART_GUI

Application Program Description

Connect Using – Set the COM Port

• COM1 (default)

• COM2

DataBits – Set the Data Bits

• 5

• 6

• 7

• 8 (default)

Parity – Set the Parity bit

• Evan

• Odd

• None (default)

• Mark

• Space

Set Mode – Set UART mode (COM2 only)

• RS232 (default)

• RS485

• RS422

Baud Rate – Set Baud Rate

Baud Rate range : 4800 ~ 230400

default : 115200

Stop Bits – Set Stop Bit

• 1

• 1.5 (default)

• 2

Flow Control – Set Flow Control mode

• Xon/Xoff

• Hardware

• None

Open – Open the specified UART COM PORT.

Close – Close the specified UART COM PORT.

Transceiver – Enter the data to be transferred.

Receiver – Display the received data.

Watchdog (WDT)

The TS200 BSP has a watchdog timer used to automatically reset the CPU if it is not periodi-

cally refreshed by software, which happens in case of a software deadlock.

Application Program Description

Current Timer – Show the counting time

Set Timer Value – Set WDT counter value

Refresh each – Set how long to clear time counter. “Refresh each” to be smaller than

“Set Timer Value”. Can be set not to perform.

Start WDT – Enable WDT count

Stop WDT – Disable WDT count.

Current Time – When the WDT is started. Display the counting time of seconds.