6

EZ3400(V) and EZ3600(V)

1.

Enter code 219 on the numeric keypad then press Select.

2.

The display will show “zerout” followed by a value.

3.

With the scale empty press the Zero key.

4.

The display will show “zero” and will return to its standard
weighing mode .

5.

Enter code 241 on the numeric keypad then press Select. The
display will show “low wt” (low weight) followed by a value.

6.

Use the numeric keypad to enter the weight where the analog
output signal should be 4mA or 0V.

7.

Press On to confirm.

8.

Enter code 242 on the numeric keypad then press Select. The
display will show “highwt” (high weight) followed by a value.

9.

Use the numeric keypad to enter the weight where the analog
output signal should be 20 mA or 5V.

10. Press On to confirm.

Analog Output Signal

The Analog Output is updated 10 times a second and reflects the
“Analog Output Gross Weight” value which is derived using
“ZEROUT”,

“LOW WT”, “HIGHWT” and “ANALOG” values. The

analog output will not necessarily follow the value displayed on the
indicator.

The “Analog Output Gross Weight” is not affected when the operator
performs a normal “Zero/Balance” of the display.