I 0 8, Delay time, Drive ratio – Digi-Star EZ 4600 Manual DataKey User Manual

Page 26: Scale id or truck id

Advertising
background image

Commonly Used Direct Access Numbers

22

EZ4600 User’s Manual

D3716-US REV D

Delay Time

Changes time indicator waits before

automatically advancing to next

feedline.

Drive Ratio

Drive ratio is number of turns seen

by sensor divided by number of

mixer rotations.

Scale ID or Truck ID

Each indicator has scale ID.

1. Enter

443

and press . Enter

delay time in seconds.

2. Press to save.

NOTE:

Set to

0

prevents automatic

advance.

1. Enter

422

and press to enter

drive ratio value.

2. Press .

1. Enter

108

and press .

2. Press to erase old ID, enter

the new ID.

3. Press .

NOTE

: TRM Tracker or Diet

Manager, software ID must match.

4 4 3

1

1

2

4 2 2

2

1

1

I 0 8

2

1

3

1

2

II:38a

08aug07

Press recipe to load

Press pens to deliver

II:38a

08aug07

Press recipe to load

Press pens to deliver