Menu 3. scale calibration settings – Digi-Star EZ 4600 Manual DataKey User Manual

Page 40

Advertising
background image

Menus and Calibration

36

EZ4600 User’s Manual

D3716-US REV D

SETTING

[display]

D.A.N

NO.

OPTIONS [displayed]

BOLD=DEFAULT

DESCRIPTION

SCALE NUMBER

(SCL NO)

231

Select scale number for

cab control

communication

REMOTE

DISPLAY

(RMDISP)

234

Select type of remote

display

MENU 3. SCALE CALIBRATION SETTINGS

DISPLAY UNIT

(lb-kg)

303

LB

/KG

Display pounds -lb or

kilograms -kg

MIMIC TYREL

(tcI300)

321

OFF

/ON

If ON -records preset

weights like a TYREL

TCX-1300 indicator.

Indicator Tracks gross

weight while batching.

MENU 4. PRESET. BATCHING & ROTATION COUNTER FEATURES

PRE ALARM

(p mthd} & {p-alm)

401

WEIGHT

PERCNT

Select weight or

percentage method, then

enter a value to activate

an early warning that

indicator is reaching the

preset.

BUZZER

(buzzer)

404

1-4,

ON

/OFF

ALARM BUZZER -allows

user to turn off alarm horn.

TIMER/

COUNTER

(tmrctr)

421

REV

TIME

Select time or mixer

revolutions to decrement

mix timer/counter.

DRIVE RATIO

(dratio)

422

0001.00

Enter the number of input

pulses that equal 1 mixer

revolution.

MANUAL

PROGRAMMING 439

PC

/SCALE

PC: Requires a Datakey

with programming.

Scale: Allows user to

manually program

indicator.

ENTRY METHOD

(E MTHD)

441

1

,2,3

Select batch 1-

amount/animal

2-percent/load

3- amount/load

TOLERANCE

(toler)

442

OFF

,.5,1-5,7,10

Select tolerance weight

percentage to accept

ingredient.

Advertising