Auto Advance

Allows hands free operation of programmed recipes. When auto advance

feature activated, indicator automatically advances to next ingredient once

tolerance, and delay time requirements met.

Tolerance

Sets Auto Advance to trigger prior to

reaching preset weight by weight or

percentage.

1. Enter

442

and press .

2. Press to choose tolerance

method.

3. Press to save.
4. To change percentage, press

until desired value is

shown. To change weight, enter

value.

5. Press to save.

NOTE

: OFF setting always

advances after preset amount

reached.

Example: Preset = 1000 lbs. If

tolerance is set to 5%, Auto

Advance will activate at 950 lbs or

95% of preset weight.

.

Pen Tolerance

Available in List Mode Only

1. Enter

462

and press .

Press again to choose

weight or percent.

2. Press , screen will display

pentol

”.

3. Enter weight or percentage

desired.

4. Press .