RE-CALIBRATING YOUR SCALE

To re-calibrate your scale, document at least 3 to 6 loads of varying sizes and measure the actual weight of all
loads on a certified scale.

It must be assured that each truck is not losing grain in transit to a certified scale.

Weigh the truck immediately before unloading and immediately after unloading to minimize errors due to
changes in fuel etc.

In this example, we are unloading six carts of grain onto four semi-trucks.

Example:

Cart Load A

51560

Cart Load B

33240

Cart Load C

17620

Cart Load D

50420

Cart Load E

38200

Cart Load F

12360

Total Indicator Weight 203400

Truckload #1

51920

Truckload #2

51320

Truckload #3

50720

Truckload #4

51070

Total Certified Weight 205030

Reading Too High
If the Indicator is reading higher than the certified scale, then the calibration number is high and should be
decreased proportionally. See page 26.

Reading Too Low
If the Indicator is reading lower than the certified scale, then the calibration number is low and should be
increased proportionally. See page 26.