Troubleshooting – Digi-Star GT465 User Manual

Page 38

Advertising
background image

38

TROUBLESHOOTING

1. Press until

DIAG

is displayed.

2. Press to enable diagnostics.

3. The 3 line display will now show value from RPM sensor.

4. Press to disable diagnostics and return to normal operation.



NOTE: The RPM value should be close t
revolution.

For best results adjust the distance between the sensor and the targ
This is equal to the thickness of one to two quarters.

Sensor has yellow LED indicator on rear to indicate target in range of the sensor.

GT465 Operators Manual

TROUBLESHOOTING

RPM Sensor Diagnostics

is displayed.

diagnostics.

The 3 line display will now show value from RPM sensor.

to disable diagnostics and return to normal operation.

The RPM value should be close to the actual RPM’s of the shaft when detecting a single target per

For best results adjust the distance between the sensor and the target to between 0.1” and 0.2” (2mm
This is equal to the thickness of one to two quarters.

Sensor has yellow LED indicator on rear to indicate target in range of the sensor.

3

D3968 Rev A

o the actual RPM’s of the shaft when detecting a single target per

et to between 0.1” and 0.2” (2mm-5mm).

1

2

4

Advertising