Digi-Star GT465 User Manual

Page 34

Advertising
background image

34

GT465 Operators Manual

D3968 Rev A

Setting/

Display

D.A.N Options

(

Bold

= Default)

Description

MENU 5. CONTROL SETTINGS

Diagnostic Enable
(

DIAG

DIAG

DIAG

DIAG

)

508

ON

, OFF

Enables diagnostic information. –
Press SELECT do display DIAG,
then press FUNCTION to display
RPM

RPM Start/Stop
Control

(rssctl

rssctl

rssctl

rssctl)

531

ON,OFF

ON, enables AUTOLOG feature

RPM/Stop Speed

(rssmin

rssmin

rssmin

rssmin)

532

300

Set to 20 – 50% of PTO operating
RPMs. Stop is activated with this
value.

Rpm Start Tol
Speed

(rsstol

rsstol

rsstol

rsstol)

533

100

Set to 10% of PTO operating
RPM’s. Start is activated using the
value + DAN 532.

RPM Start Delay

(rsstoy

rsstoy

rsstoy

rsstoy)

534

3.0

Start activated when RPMs above
DAN 532 + DAN 533 for this time in
seconds.

RPM Stop Delay

(rsspoy

rsspoy

rsspoy

rsspoy)

535

2.0

Stop activated when RPMs below
DAN 532 for this time in seconds.

CALIBRATION

Setup Number

(

SETUP

SETUP

SETUP

SETUP

)

871

Quick entry method selects weigh
method 1-4lbs, 5-8kg, gain 1-9,
display counts 1-9 and capacity
*1000.

Calibration Number

(

CAL

CAL

CAL

CAL

)

872

Weight displayed at .4mV/V for
these load cells.