Calibrating scale for maximum accuracy – Digi-Star SW2600EID User Manual

Page 33

Advertising
background image

Operators Manual

D3718

33

Calibrating Scale for Maximum Accuracy

First write down current SETUP and CAL numbers of indicator. These

numbers are displayed during self test. To run self test with indicator

already ON, press “On”. Press “On” pauses self test while numbers

displayed. Press “On” again to resume.

SETUP # _______________ CAL # ________________

A large amount of known weight needed to calibrate scale. For best results

have at least as much weight as largest load to weigh.

Determining New Setup and Calibration Numbers.

Zero-Balance scale so display reads zero.

Put KNOWN WEIGHT on scale platform and write down WEIGHT

DISPLAY. Perform the following equation to find ACCURATE CAL #.

KNOWN WEIGH T

WEIGHT DISPLAY

Example:

The KNOWN WEIGHT 1000lbs, but WEIGHT DISPLAY 950lbs. The

EXISTING CAL # is 776.

1000

950

817 is the ACCURATE CAL #. The setup number does not change.

X EXISTING CAL # = ACCURATE CAL #

X 776 = 817

Advertising