Weighing errors – Digi-Star SW2600EID User Manual
Page 39
Operators Manual
D3718
39
WEIGHING ERRORS
OVRCAP
Capacity Limit:
Display shows message "OVRCAP" if weight on scale system exceeds
capacity limit. Capacity value entered in SETUP to warn of overloading
scale system.
+RANGE
Over Range:
Display show message "+RANGE" if weight on scale system exceeds
maximum weight measurable by scale system. Over range value always
system’s maximum A/D counts multiplied by scaling factor. Actual weight
at which over range occurs depends on calibration, zero, and display count
size.
-RANGE
Under Range:
Display shows message "-RANGE" if weight on scale system less than
minimum weight measurable by scale system. Under range value always
system’s minimum A/D counts multiplied by scaling factor. Actual weight at
which under-range occurs depends on calibration, zero, and display count
size.
NOTE:
EZII Series supports –RANGE that is equal to +RANGE in absolute
value.