Scoreboard methods – Digi-Star SW600 User Manual

Page 17

Advertising
background image

Operators Manual

SCOREBOARD METHODS

Scoreboard methods 1 through 6 are used for the Stock Weigh 600. Many
other scoreboard methods are available but are not used.

1. Transmit numeric display data once per second.

2. Transmit numeric display data two times per second.

3. Transmit numeric display data three times per second.

4. Transmit numeric display data at the A-D conversion rate.

5. Transmit numeric display data at the display rate.

6. Transmit numeric display data whenever there is a display weight

change.

NOTES:

When using SCOREM = 1, 2, 3, 4, 5 and 6 be sure to set
LSTORE = OFF, TAREAP = OFF and APRINT = OFF to avoid
corrupted data when transmitting scoreboard data and printing
scale data.

With COM IN set to EZ2CMD the port configuration is: 9600
Baud, 1 start bit, 7 data bits, 1 even parity bit and 1 stop bit.

With COM IN set to EZCMD the port configuration is:1200
Baud, 1 start bit, 7 data bits, 1 even parity bit and 1 stop bit.


D3656

17

Advertising