Operators Manual

D3660

3

The EZ indicator a factory-installed and configured radio that is assigned a unique scale

number (SCL NO). Two indicators cannot operate using the same scale number. The

following setup parameters are required for proper radio operation:

- (Select – )

NOTE: For best performance on systems with six or less indicators, use scales numbered

1 - 6.

Change Scale Number on Indicator Using Long Form Setup

NOTE: Perform this process on the indicator front panel (Do not use Cab Control).

1. Enter the Long Form Setup by holding [Net-Gross] and pushing [On] for three

seconds.

2. Press [Net/Gross] or [Select] to advance to

.

3. Press [On] to advance to

4. Press [Net/Gross] or [Select] to set to .
5. Press [On] to save setting and advance to

.

6. Press [Net/Gross] or [Select] to set to desired scale.
7. Hold [Tare] and press [On/Off] to return to indicator operation.
8. Press [On] to save setting and advance to end of menu.