Digi-Star EZ3400(V) User Manual

Page 32

Advertising
background image

List with direct access numbers

D3714-GB Rev B EZ3400(V) User' s manual

28

Setting

[display]

Access

Options [displayed]

(bold=default)

Description

MENU 3. CALIBRATION SETTINGS WEIGHING INDICATOR

DISPLAY UNIT

[

lb-kg]

303

LB/KG

Display in lb or kg.

MENU 4. PRESET, RECIPE & COUNTER FUNCTIONS

PREALARM

[

P MTHD] & [P-ALM]

401

WEIGHT

PERCENT

Select WEIGHT or PERCNT and

enter a value to activate an early

warning indicating that the weighing

indicator is reaching the preset

amount.

SIREN

[BUZZER]

404

1-4, ON/OFF

Switching the loud alarm signal ON

or OFF.

TIMER/COUNTER

[

TMRCTR]

421

REV.
TIME

Determination of the recipe mixing

time based on time or on the

number of mixing auger revolutions.

DRIVE RATIO

[

DRATIO]

422

0001.00

The number of input impulses (PTO

revolutions), which correspond with

one single revolution of the mixing

auger.

TOLERANCE

[

TOLER]

442

OFF,.5,1-5,7,10

The tolerance (percentage of the

ingredient amount) to accept the

ingredient.

INGR. ADVANCE DELAY

[

DELAY]

443

MANUAL, 1-3,5,7,

10,20,30,60

The number of seconds the

weighing indicator should wait

before automatically advancing to

the next ingredient.

USER ID

[

USERID]

446

ON/OFF

If this setting is

ON, the operator

should enter the user ID to use the

weighing indicator.

RECIPE TOTAL

[

RECTOT]

451

ON/OFF

Displayed total weight of the recipe

to be loaded.

TOLERANCE OVERLOCK

[

OVERLK]

453

ON/OFF

If this setting is

ON, the weighing

indicator does not automatically

advance to the next ingredient when

exceeding the set tolerance.

Advertising
This manual is related to the following products: