Fume extraction – Dometic RM 6270(L) User Manual

Page 22

Advertising
background image

22

Fume extraction

Fume extraction must be arranged in such a way as to provide complete

extraction of all products of combustion to an area outside the living area.

The flue system must slope in an upward direction in order to avoid a

build-up of condensation.

Fitting the fume flue in the upper ventilation grille

1. Connect T-piece (E) to

adaptor (F) or flue pipe

(K) as required and affix

with screw (G). Ensure

that heat baffle (H) is

lodged in the correct

position.

2. Insert flue pipe with cover

plate (C) through the

appropriate aperture in

frame (I) and connect to

T-piece (E). If necessary,

shorten flue pipe (C) to

the required length.

3. Insert ventilation grille

(D) into mounting frame

(I) and fasten, using the

locking handle on the left

of the grille.

4. Put cap (B) on flue pipe (C).
5. Insert extractor insert (A) into ventilation grille (D).
This type of fume extraction allows use a winter cover.