ŸŸ

The gas connection to the appliance is effected by means of a suitable

coupling tube fitting L8, DIN 2353-ST, complying with European Standard

EN 1949 (e.g. Ermeto).

The gas connection may only be carried out by a qualified personnel.

Following proper installation, a testing for

leakage and a flame test must be carried out

by *qualified personnel in compliance with

EN1949 .
A certificate of testing must be issued.
* qualified personnel
Qualified personnel are accredited experts

who are able, by virtue of their training

and knowledge, to vouch for the correct

implementation of the leakage test.

The refrigerator must be equipped with a

gas cock (C) in the supply line to allow the

supply to be disconnected. Such a cutout

device must be readily accessible to the user.

SW 14

SW 17

C

Gas-pressure

BE

X

DK

X

DE

X

X

FI

X

FR

X

GR

X

X

IE

X

X

IS

X

IT

X

LU

X

X

NL

X

X

NO

X

AT

X

X

PT

X

X

SE

X

CH

X

X

ES

X

UK

X

X

X

Category I

3P(30)

I

3P(37)

I

3P(50)

I

3+

I

3B/P(50)

I

3B/P(30)

mbar 30

37

50

28-37

30-37

50

30