3. Wiring diagram with automatic ignition and no interior light

4. Wiring diagram with automatic ignition and interior light

spark plug

light DC --

reed contacts

(sensor switching)

* resistor (replaced by a bridge for 24V battery voltage)

ignition

control

lamp

thermo cut-off current

mains connection

~

to casing

heating-

element

AC

~

ground

battery connection

12V/24V --

mains connection

~

to casing

thermo cut-off current

heating-elem

ent

DC

-

reigniter

spark plug

to casing

to casing

heating-

element

AC

~

from battery

heating-element

DC

-

Battery connection 12V/24V -
A = Ground heating element DC, white
B = Heating element DC-,

red

C = Ground automatic ignition, black
D = Automatic ignition

violet

ground

ignition

control

lamp

to casing

battery connection

12V/24V --

* resistor

to casing

Battery connection 12V/24V -

A = Ground heating element DC, white
B = Heating element DC-,

red

C = Ground, automatic ignition black

and interior light,

D = Automatic ignition and violet

interior light

from

battery

Advertising