Flowserve U-MAG INNOMAG User Manual

Page 31

Advertising
background image

U-MAG ENGLISH 26999990 10-14

Page 31 of 40

directly across from the drive pins. Set screw (B)
will be perpendicular to the drive pins.


Figure 6-21

f)

Align outer magnet assembly [0230] drive pins
with the key groove on the motor shaft.

g)

Use a ruler, straight edge or visually align the
groove on the outer magnet assembly [0230] with
the outer edge of the adapter [1340].

Figure 6-22

h)

Remove metal plug [6569] from the top of the
adapter [1340].

i)

Looking through the top plug hole on the adapter
[1340], line up the row of drive pins on the outer
magnet assembly [0230] with the hole as shown
in Figure 6-23.

Figure 6-23

j)

Rotate the outer magnet assembly [0230] by
180°. Visually inspect concentricity of the outer
magnet assembly [0230] with adapter [1340].

k)

Tighten the visible set screw (A) as shown in
Figure 6-18.

l)

Rotate the outer magnet assembly [0230] 90°
counterclockwise to locate and tighten set screw
(B).

m)

Install the metal plug [6569] on the adapter
[1340].

6.13.2 IEC Drive End Assembly

The IEC adapter requires the

installation of dowel pins for the following motor sizes:
100L and 112M. The pin installation is permanent.
Check the configuration for your motor before you
begin.

a)

IEC 80 & IEC 90 do not require dowel pins.

b)

IEC 100L and 112M require (6) dowel pins
installed into the unpainted dowel pin holes.
Firmly pound the (6) dowel pins in with a hammer
until they are firmly seated. The properly installed
dowel pin will be flush with the adapter [1340]
face.

Figure 6-24

Figure 6-25

c)

IEC 132 motors require an adapter plate. To
install, align the inner holes on the adapter plate
with the holes on the bottom of the adapter [1340].
Insert and tighten the (4) bolts to the adapter plate.

Figure 6-26