Storage, Recycling and end of product life, Description – Flowserve TB-MAG INNOMAG User Manual

Page 11: Configurations, Nomenclature

Advertising
background image

INNOMAG® TB-

MAG™ ASME and ISO SEALLESS ENGLISH 26999988 06-14

Page 11 of 44

Vertical pumps with motor installed: Vertical pumps must
use non-footed vertical motors with two eye bolts. Place
one sling around the pump discharge nozzle and one
around the suction. Run the slings up through the eye
bolts on the motor to keep pump from tipping when lifted.

Assembled units and their parts are

heavy. Failure to properly lift and support this
equipment can result in serious physical injury and/or
equipment damage. Lift equipment only at the
identified lifting points. Lifting devices such as
eyebolts, slings, and spreaders must be rated,
selected, and used for the entire load being lifted.

Crush hazard. The unit and the components can

be heavy. Use proper lifting methods and wear steel-
toed shoes at all times.

Do not attach sling ropes to shaft

ends.

Make sure that the unit cannot roll or

fall over and injure people or damage property.

These pumps use carbon or ceramic silicon carbide
components. Do not drop the pump or subject it to
shock loads as this can damage the internal ceramic
components.

2.4 Storage

Store the pump in a clean, dry

location away from vibration. Leave piping
connection covers in place to keep dirt and other
foreign material out of pump casing.

The pump may be stored as above for up to 6
months. Consult Flowserve for preservative actions
when a longer storage period is needed.

2.5 Recycling and end of product life


At the end of the service life of the product or its
parts, the relevant materials and parts should be
recycled or disposed of using an environmentally
acceptable method and local requirements. If the
product contains substances that are harmful to the
environment, these should be removed and disposed
of in accordance with current regulations.

Make sure that hazardous substances are

disposed of safely and that the correct personal
protective equipment is used. The safety
specifications must be in accordance with the current
regulations at all times.

3 DESCRIPTION

3.1 Configurations


The TB-

MAG™ chemical process pumps are

fluoropolymer lined, magnetically coupled, single
stage, thrust balanced, centrifugal pumps. Pump
options include ASME and ISO horizontal as well as
ASME vertical. The horizontal version of the TB-
MAG

™ pump line conforms to the dimensional

specifications noted in ISO 2858 for ISO pump sizes
and ASME B73.3 for ASME pump sizes although a
few exceptions do exist. Both have centerline
discharge.

3.2 Nomenclature


The pump size will be noted on the nameplate as in
this example: A161311100-AD0. See the following
charts for pump identification codes.

Advertising