1.6.4.5 Preventing sparks

To prevent a potential hazard from mechanical

contact, the coupling guard must be non-sparking.

To avoid the potential hazard from random induced
current generating a spark, the earth contact on the
baseplate must be used.

Avoid electrostatic charge: do not rub non-metallic

surfaces with a dry cloth

;

ensure cloth is damp.


When applicable the coupling must be selected to
comply with 94/9/EC and correct alignment must be
maintained.

Additional requirement for metallic pumps on
non-metallic baseplates

When metallic components are fitted on a non-
metallic baseplate they must be individually earthed.

1.6.4.6 Preventing leakage

The pump must only be used to handle liquids

for which it has been approved to have the correct
corrosion resistance.

Avoid entrapment of liquid in the pump and associated
piping due to closing of suction and discharge valves,
which could cause dangerous excessive pressures to
occur if there is heat input to the liquid. This can occur if
the pump is stationary or running.

Bursting of liquid containing parts due to freezing
must be avoided by draining or protecting the pump
and ancillary systems.

Where there is the potential hazard of a loss of a seal
barrier fluid or external flush, the fluid must be monitored.

If leakage of liquid to atmosphere can result in a
hazard, the installation of a liquid detection device is
recommended.

1.6.4.7 Maintenance of the centrifugal pump to
avoid a hazard

CORRECT MAINTENANCE IS REQUIRED TO

AVOID POTENTIAL HAZARDS WHICH GIVE A
RISK OF EXPLOSION

The responsibility for compliance of maintenance
and compliance during maintenance with the
specified product is with the plant operator.

To avoid potential explosion hazards during
maintenance, the tools, cleaning and painting
materials used must not give rise to sparking or
adversely affect the ambient conditions. Where there
is a risk from such tools or materials, maintenance
must be conducted in a safe area.

It is recommended that a maintenance plan and
schedule is adopted. (See section 6, Maintenance.)

1.7 Nameplate and safety labels


1.7.1 Nameplate
For details of nameplate, see the Declaration of
Conformity
and section 3.

1.7.2 Safety labels

Oil lubricated units only:

DurcoShield

TM

(Splash/Shaft Guard) only:

THIS DEVICE IS NOT A CONTAINMENT
SYSTEM NOR A SEAL BACKUP SYSTEM
IT IS A LIMITED PROTECTION DEVICE.
IT WILL REDUCE BUT NOT ELIMINATE
THE PROBABILITY OF INJURY.

Advertising