Flowserve MF User Manual
Page 24
MF USER INSTRUCTIONS ENGLISH 71569191 12/04
Page 24 of 50
®
5.2.2.1 Bearing housing showing oil fill/vent and oil level checker (typical)
This is a STATIC oil level and the oil level will drop during operation; verify that the vent plug is
properly installed so that a false level is not realized.
BEARING
LOCKWASHER
LOCKWASHER
LOCKNUT
THRUST
BEARING
OIL FILL/VENT
SHIM
LINE BEARING
OIL THROWER
SEAL
SHAFT
SEAL
THRUST
BEARING
COVER
BEARING
FRAME
LEVEL
CHECK
LINE
BEARING
COVER
STUFFING
BOX HEAD
OIL
VENT CAP
OIL FILL
SIGHT GAUGE
OIL LEVEL
OIL DRAIN
PLUG
PUMP SHAFT
OIL LEVEL
5.2.3 Bearings–grease lubricated
MF pumps are normally furnished with grease lubricated bearings. Grease fittings are provided on the line and
thrust bearing ends of the bearing housing; see detail below. Before starting the pump, check the bearing
frame cavities for grease and add grease as necessary. For suggested frequency and grease quantity for re-
lubrication, refer to section 5.2.6.2
Proper grease lubrication is very important. Anti-friction bearings can be over-greased as well as under-
greased. After start up, remove the grease fittings or pipe plug closest to the cover and allow the excess
grease to flow out.