3 general arrangement drawing, 9 certification, 10 other relevant documentation and manuals – Flowserve MF User Manual
Page 49: 1 supplementary user instructions
MF USER INSTRUCTIONS ENGLISH 71569191 12/04
Page 49 of 50
®
Constant level oiler
77A
77B
60
8.2.1 Parts list - MF oil lubricated
ROTATING PARTS
REF.
NO
QTY
REQ’D
DESCRIPTION
2
1
Impeller
6
1
Pump shaft with keys
8
1
Impeller wearing ring
14
1
Shaft sleeve
16
1
Line bearing
18
1
Thrust bearing
22
1
Bearing lock nut
22A
1
Bearing lock washer
24
1
Impeller screw
24A
1
Plate, impeller
40
1
Deflector
60
2
Oil slingers
STATIONARY PARTS
1
1
Casing
11
1
Head, stuffing box
13
5 rings
Packing
17
1
Gland split
29
1
Seal cage split
35
1
Line bearing cover
37
1
Thrust bearing cover
49
1
Seal ring (outboard)
59
1
Handhole cover
67
1 set
Adjusting shims
73
1
Seal, ring
73A
1
Casing gasket
73B
1
Handhole cover gasket
77A
1
Constant level oiler
77B
1
Vent cap
89
1
Thrust bearing cover ring seal
99
1
Bearing frame
8.3 General arrangement drawing
The typical general arrangement drawing and any
specific drawings required by the contract will be sent
to the Purchaser separately unless the contract
specifically calls for these to be included into the
User Instructions. If these drawings are sent
separately, the purchaser must retain those with the
User Instructions.
9 CERTIFICATION
Certificates determined from the Contract
requirements are provided with these Instructions
where applicable. Examples are certificates for CE
marking, ATEX marking etc. If required, copies of
other certificates sent separately to the Purchaser
should be obtained from the Purchaser for retention
with these User Instructions.
10 OTHER RELEVANT
DOCUMENTATION AND MANUALS
10.1 Supplementary user instructions
Supplementary instructions such as for a driver,
instrumentation, controller, seals, sealant system etc
are provided as separate documents in their original
format. If further copies of these are required they
should be obtained from the supplier for retention
with these User Instructions.
10.2 Change notes
If any changes, agreed with Flowserve Pump
Division, are made to the product after its supply, a
record of the details should be maintained with these
User Instructions.