2.8 Using the same high temperature

grease as above, coat both halves

of the bearing housing in the

spherical joint area.

2.9 Slide the half of the housing without

the pin slot around the carrier as-

sembly. Align the housing split with

the split in the carrier assembly.

The flat side of the housing should

point down.

2.10 Place the other half of the housing

around the carrier assembly. Orient

the carrier assembly so that the pin

enters the pin slot in the housing.

Rotate the carrier assembly slightly

and/or move it axially on the shaft

to achieve alignment.

2.11 Secure the halves of the hous-

ing together using the two (2) cap

screws. Tighten cap screws to a

torque value of 27 N-m (20 ft-lbs).

The halves should come together

so there is full metal-to-metal con-

tact in the joint. The housing should

grip the carrier tight enough to hold

a fixed position, but moveable with-

out requiring mechanical leverage.