Description

The 86/87 seals are cartridge mounted mechanical seals, designed for

ease of installation and reliable operation. No seal setting dimensions

are required. Rotatable centering tabs provide proper alignment. The

flexible stator design compensates for inadvertent misalignment of the

seal chamber face. Multiple springs provide uniform face loading and

are external of the pumpage, resisting clogging or hang-up. Installation

according to the following steps will assure long trouble free life of

the 86/87 seals.

Equipment Check

1.1 Follow plant safety regulations:

• lock out motor and valves.

• wear designated personal safety equipment.

• relieve any pressure in system.

• consult plant MSDS files for hazardous material regulations.

1.2 Disassemble equipment to allow access to seal installation area.

1.3 Remove existing mechanical seal and gland or compression

packing and packing gland.

1.4 Make sure the shaft or sleeve and the seal housing face are

clean and free of burrs, cuts, dents, or corrosion that might cause

leakage past the sleeve packing or gland gasket. See Figure 1 & 2.

Replace worn shaft or sleeve if it is worn in the sleeve packing

area. Remove sharp edges from keyways and threads.