3 piping – Flowserve 80 Series Five Star Seal User Manual

Page 8

Advertising
background image

8

3 Piping

3.1 Taps

b

and

c

in the gland are buffer/barrier fluid inlet and

outlet ports. Use Figure 7 to determine which ports to use as inlet

and outlet.

3.2 For dual seal pressurized seal operation, supply a clean compat-

ible barrier fluid to the inlet port at a pressure at least 170 kPa

(25 psi) above the stuffing box pressure. See Figure 8. Flowserve

can supply information on barrier fluid flow requirements based on

seal size, product temperature, barrier fluid characteristics, and

shaft speed. Consult Flowserve, Flow Solutions for assistance.

Inlet

Outlet

Clockwise (CW)

Port

c

Port

b

Counterclockwise (CCW)

Port

b

Port

c

CCW


Rotation

CW


Rotation

b

c

Note: Outlet port position should be located above Inlet

port for optimum operating performance