4.1 Repair Procedures

4.1.1 These instructions are to be used in conjunction with the P-50

Repair Kit. The Repair Kit contains replacement seal faces, sec-

ondary seals, and other special hardware. The parts are identified

in Figure 7. The repair should be done in a clean, well lit area. The

tools you will need to do the repair include:

• Alcohol

• Paper towels or cloths

• Small screw driver

• 1/8" Allen wrench (provided)

• 3/32" Allen wrench (provided)

• 3/16" Allen wrench (provided) for sizes> 2.250 inch

Stator

Rotor

O-rings

Set Screws

Centering

Tabs

Retaining Ring

Gasket

O-ring

Springs

O-ring

Half Dog

Set Screws

For special problems encountered during the repair procedure,

contact your nearest Flowserve Sales and Service Representative.

Figure 7

Figure 8

4.2 Disassembly

4.2.1 Replace the centering tabs on the

sleeve collar before removal of the

gland bolt nuts.

4.2.2 Remove the seal from the pump.

4.2.3 Remove and discard the centering

tabs and set screws.

4.2.4 Remove the sleeve collar.

4.2.5 Turn the assembly "gasket side up"

and lift out he sleeve and rotor.

See Figure 8.