Failure

Probable Cause

Corrective Action

Valve moves to failure position, exces-

sive air bleeding from transfer case

. Failure of cylinder actuator O-ring

. Replace actuator O-ring

. Failure of sliding seal assembly in cyl-

inder actuator

. Repair or replace sliding seal assembly

Jerky shaft rotation

. Overtightened packing

. Retighten packing box nuts to slightly over finger-tight for

V-ring packing, 4 ft-lbs/9 Nm for braided packing.

. Improper adjustment of lever arm on

shaft causing arm to contact transfer

case

. Redjust lever arm (see step  in Actuator Remounting)

3. Cylinder wall of actuator not lubri-

cated

3. Lubricate cylinder wall with silicone lubricant

4. Worn piston O-ring allowing piston to

gall on cylinder wall

4. Replace O-ring; if galling has occurred replace all damaged

parts

5. Worn actuator stem O-ring causing

actuator stem to gall on stem collar

5. Replace O-ring; if actuator stem is galled replace it

6. Worn (or damaged) thrust bearings,

shaft bearing or packing followers

6. Disassemble and inspect parts; replace any worn or dam-

aged parts

Excessive leakage

. Improper adjustment of external

stroke stops

. See Actuator Remounting

. Improper seat adjustment

. See Seat Replacement

3. Worn or damaged seat

3. Replace seat

4. Damaged plug seating surface

4. Replace plug

5. Improper handwheel adjustment act-

ing as limit stop

5. Adjust handwheel until plug seats properly

Leakage through line flanges

. Dirty line gasket surfaces

. Clean gasket surfaces and reinstall valve

. Improper sealing of line flanges

. Tighten line flanges evenly and completely (see Table  for

proper torque)

3. Flange or pipe misalignment

3. Reinstall valve in line; check piping system

Leakage through packing box

. Loose packing box nuts

. Tighten packing box nuts to slightly over finger-tight for

V-ring packing, 4 ft-lbs/9 Nm for braided packing.

. Worn or damaged packing

. Replace packing

3. Dirty or corroded packing

3. Clean body bore and stem, replace packing

Valve slams, wont open, or causes se-

vere water hammer

. Improper valve installation

. See step  in Installation and correct flow direction

Shaft rotates, plug remains open or

closed

. Broken shaft

. Replace shaft, make sure plug does not overstroke and

contact plug stop

Actuator operates, shaft does not rotate

. Broken internal actuator parts

. Refer to appropriate actuator maintenance instructions

Leakage through bonnet joint; leakage

from end post

. Loose bolting or damaged gasket

. Tighten bolting as recommended in Table II

. Dirty gasket surfaces

. Clean gasket surfaces, replace gaskets and retighten bolt-

ing per Table II

3 - Air Action

4 - Pipe Configuration

5 - Actuator Orientation

6 - Shaft Direction

O

Air-to-open - ATO

L

Left Hand Mounting

L

Left

U

Shaft Upstream

C

Air-to-close - ATC

R

Right Hand Mounting

R

Right

D

Shaft Downstream

D

Flow Down

T

Top (Default)

U

Flow Up

B

Bottom*

AT

3

4

5

6

* Not available on diaphragm actuators