Flowserve Valtek MaxFlo 3 User Manual

Page 3

Advertising
background image

®

User instructions - MaxFlo 3 - VLENIM0052-02 02.07

3

STOP!

WARNING: Before products are returned to Flowserve

for repair or service, Flowserve must be provided with a

certificate that confirms that the product has been decon-

taminated and is clean. Flowserve will not accept deliver-

ies if a certificate has not been provided (a form can be

obtained from Flowserve).

1.8

Storage

In most cases, Flowserve products are manufactured

from stainless steel. Products not manufactured from

stainless steel are provided with an epoxy resin coating.

This means that Flowerve products are well protected

from corrosion. Nevertheless, Flowserve products must

be stored adequately in a clean, dry, environment. Plastic

caps are fitted to protect the flange faces and prevent

the ingress of foreign materials. These caps should not

be removed until the valve is actually mounted into the

system.

2

UNPACKING

.

While unpacking the valve, check the packing list against

the materials received. Lists describing the valve and ac-

cessories are included in each shipping container.

.

When lifting the valve from shipping container, use

straps through the yoke legs. Take care to position lifting

straps to avoid damage to the tubing and mounted ac-

cessories.

WARNING: When lifting a valve be aware that the center

of gravity may be above the lifting point. Therefore, sup-

port must be given to prevent the valve from rotating.

Failure to do so can cause serious injury to personnel

and damage to the valve and nearby equipment.

.3

Contact you shipper immediately if there is shipping

damage.

.4

Should any problem arise, call your Flowserve represent-

ative.

DANGER: Before installation check the order number, se-

rial number, and/or the tag number to ensure that the

valve and actuator being installed are correct for the in-

tended application.

CAUTION: Do not insulate extensions that are provided

for hot or cold services.

3

INSTALLATION

3.

Before installing the valve, clean the pipeline of all con-

tamination, carbon deposits, welding chips, and other

foreign material. Carefully clean gasket surfaces to en-

sure a tight seal. Pipelines must be correctly aligned to

ensure that the valve is not fitted under tension.

3.

Fire protection must be provided by the user.

3.3

Check the direction of fluid flow to ensure that the valve

is correctly installed. Flow direction is indicated by the

arrow attached to the body. All installation orientations

for fitting the valve into the pipeline are defined at the end

of this manual.

DANGER: To avoid serious injury, keep hands, hair, cloth-

ing, etc away from the plug and seat when the valve is

working.

3.4

Whenever possible, the valve should be installed so that

actuator is in an upright position. Vertical installation of

the actuator permits easier valve maintenance.

3.5

Connect the air supply and instrument signal lines. Throt-

tling control valves are equipped with a valve positioner.

Connections are marked for the air supply and the in-

strument signal. Check that the actuator and positioner

can withstand the maximum air supply from the network.

The required air supply is indicated on a sticker located

on the actuator. An air regulator will be necessary in cer-

tain cases in order to limit the supply pressure. A filter

is recommended unless the air supplied is exceptionally

clean and dry (air quality without humidity, oil, or dust

as per IEC 770 and ISA-7.0.0). All connections must be

completely tight.

CAUTION: On valves equipped with air filters, the air filter

must point down to perform properly.

3.6 Use the bolts indicated in table I for installing the valve

in the pipeline, and then tighten alternately according to

good practice. The user must in all cases confirm the

capacity of the bolts to ensure a sufficiently tight gasket

seal for the expected service conditions.

3.7

Be sure to provide proper overhead clearance for the

actuator to allow for disassembly of the actuator from

the valve body. Refer to the appropriate to the MaxFlo 3

Technical Bulletin for proper clearances. The MaxFlo 3

Technical Bulletin is available at www.flowserve.com.