Wiring – Flowserve NRGT26-1 User Manual

Page 16

Advertising
background image

6

Wiring

Use multi-core flexible control cable with min. conductor size .5 mm

2

for wiring.

.

Undo screws

H

, remove housing cover

J. Fig. 7

2. Unscrew union nuts of cable entry

I.

The electrode terminal can be turned through +/– 180 °.
3. Loosen plug

U with 7 mm spanner but do not remove. Fig. 8

4. Turn electrode terminal into desired direction (+/– 80 °).
5. Tighten plug

U slightly.

6. Remove terminal strips

S from board.

7. Connect terminal strip according to wiring diagram, connect PE connection

T.

8. Plug in terminal strips

S.

9. Install cable entry

I.

0. Replace housing cover

J, insert screws H and fasten.

NRGT 261, NRGT 261S

Fuse supply cables with 250 mA (slow blow).

Tools

Attention

Wiring diagram

Screwdriver for cross head screws, size

Screwdriver for slotted screws, size 2.5; completely insulated according to DIN VDE 0680-

Open-end spanner 7 mm A. F.

Fig. 13

Thermal fuse

Mains

24 V DC

4-20 mA

Max. load

500

Earthing screw

in enclosure

NRGT 261

NRGT 261S

Advertising