See Fig. 2

NRGT 261, NRGT 261S

Technical Data

Type Approval N°

NRGT 26-:

TÜV · WRS · 02-39

NRGT 26-S:

LR 98/20075

RINA ELE/30298/2

GL 99249-96HH

BV 067/AO BV

NKK A-556

DNV A-8394

KR HMB 0690-MS002

Max. service pressure

32 bar g at 238 °C
Connections

NRGT 26-:

Screwed ¾" BSP, DIN ISO 228-

NRGT 26-S:

Flanged DN 50, PN 40, DIN 2635

Materials

Case:

Die cast aluminium 3.26 (G AlSi8Cu3)

Stem:

S. S. .457 CrNiMoTi7-2-2

Flange:

Forged steel .0460 P250GH

Measuring electrodes: S. S. .457 CrNiMoTi7-2-2

Electrode insulation:

PTFE

Spacer disc:

PTFE (design for marine applications)

Mains supply

230 V +/- 0 %, 50/60 Hz

5 V +/- 0 %, 50/60 Hz (option)

2

24 V +/- 0 %, 50/60 Hz (option)

24 V DC

Length supplied / measuring range

NRGT 261
1 Max. installation length at 238 °C

2 Measuring range

300
400
500
600
700
800
900
000
00
200
300
400
500
2000

275
375
475
575
675
775
875
975
075
75
275
375
475
975

36
420
526
63
737
842
947
053
57
262
366
47
579
2099

373
477
583
688
794
899
004
0
24
39
423
528
636
256

NRGT 261 S
3 Max. installation length at 238 °C

4 Measuring range

1

2

3

4

See Fig. 3