2.5 Initial Operation

Before initial operation of the actuator, perform the following checks:
• Check that all electrical supply, control and signal lines are properly connected, by following the dedicated customer

procedures.

• Check that the pressure and quality of the supply fluids are as prescribed.
• Check the absence of leaks in the pneumatic connections. If necessary tighten the pipe fittings.

2.6 Fail Open and Fail Close Configuration

The actuator is designed for work in both configurations: fail open and fail close. For conversion from one configuration

to the other, refer to next paragraph.

Figure 5: Actuator Configuration: Fail Close – Fail Clockwise – Single Acting

Figure 6: Actuator Configuration: Fail Open – Fail Counter Clockwise – Single Acting

9

LPC Compact Actuator Series FCD LFENIM0002-00-AQ 07/14

flowserve.com